Produced water treatment Produced water operation - key features • Water quality OiW <5 mg/l • Recovery rate ~95 % • Flux rates from 100 - 300 LMH • Low TMP 0.02 – 0.6 bar • Cross Flow 2 m/s • Automated backwash system • Automated CIP system Terminology • TMP - Transmembrane Pressure: The driving force for the membrane separation • Flux - LMH - litre / m2 / hour: Flow per unit area for a specific TMP • Cross flow: Flow in individual membrane channels • Backwash: Backwash cleaning with permeate water • CIP - Cleaning in Place: Chemicel cleaning when backwash is inadequate to maintain permeability Designed for the future When using our modular design you can plan ahead. A typical platform experiences an increase of produced water during its lifetime. SemCoMem gives you the opportunity to use the same basis design and then increasing the capacity of the unit - module by module - as the requirements change. By doing this, you never experience overcapacity of your water treatment systems. SEMCO MARITIME A/S reserves the right to make changes without prior notice. © 2017, SEMCO MARITIME A/S and the SEMCO MARITIME Group of Companies. Dropbox\Marketing\Product flyers\SemCoMem 210817 subh For further information, addresses, email addresses and phone numbers - please see our website: www.semcomaritime.com