DATASHEET - SB 125-1 Ex SOUNDER /BEACON AUDIBLE & VISUAL SIGNALLING EQUIPMENT TECHNICAL DATA M AT E R I A L COLOUR INGRESS PROTECTION AMBIENT TEMPERATURE FOR OPERATION C E R T I F I C AT I O N EX CODE S TA N D A R D ATEX AREA ZONE CANDELA LENS COLOR LIGHT TYPE TRUE LIGHT INTENSITY PEAK LIGHT INTENSITY TIME LIFE BLINKING OR ROTARY FREQUENCY (0 = steady status) CONSUMPTION BEACON AMBIENT HUMIDITY* POWER SUPPLY RATED IMPULSE WITHSTAND VOLTAGE WORKING CURRENT LED WORKING CURRENT XENON CONSUMPTION SOUNDER CURRENT CONSUMPTION SIGNALLING TYPE NOISE LEVEL CABLES ENTRY TERMINAL NET WEIGHT EXTERNAL TRIGGER** • ENCLOSURE & BRACKET: Stainless steel 316L • LENS: Tempered borosilicate glass 3.3 • RED : RAL 3001 - YELLOW** : RAL1018 - BLUE** : RAL5005 - BLACK** : RAL9005 • IP66/67 • T6 = - 40°C ~ + 55°C , T5 = - 40°C ~ + 60°C, T4 = - 40°C ~ + 70°C • Nemko 13 ATEX 1566X, IECEX NEM 13.0036X • II 2 GD Ex d IIC T4 ~ T6 Gb, Ex tb IIIC T135°C ~T85°C, • EN / IEC 60079-0, EN / IEC 60079-1, EN / IEC 60079-31, EN 54-3 • Gas zone: 1 & 2 Dust zone: 21 & 22 • Red: 0.15 • Amber: 0.51 • Blue: 0.12 • Green: 0.49 • Clear: 1 Flash tube (XENON) LED • 5 joules = 109 Cd • 15 joules = 395 cd • 10 joules = 293 Cd • 21 joules = 424 Cd • 5 W = 128 Cd • 10W = 312 Cd • 5 joules = 35970 Cd • 10 joules = 66804 Cd • 15 joules = 83345 Cd • 21 joules = 95824 Cd • Emissions are reduced to 70% after 8 million flashes • >50 000 hours without luminosity decreasing • 60/80/120 times/min • 100/120/150 times/min • 120/150/180 times/min • 60/75/0 times/min • 60/75/100 times/min • 75/95/0 times/min • 75/95/120 times/min • 5 Joules = 10W • 15 Joules = 20W • 10 Joules = 15W • 21 Joules = 25W • 5W • until 95%* • 12-48V DC • 12-48V AC (50/60hz) • 1kV following IEC 61000-4-5 • Power • 5W • 10W 12V DC 530 mA 1100 mA 24V DC 260 mA 530 mA 48V DC 120 mA 240 mA • 10W • 100-240V AC (50/60hz) 110V AC 80 mA 160 mA 220V AC 40 mA 80 mA • Energy • 5J • 10J • 15J • 21J 12V DC 460 mA 850 mA 1200 mA NA 24V DC 280 mA 490 mA 700 mA 960 mA 48V DC 140 mA 250 mA 360 mA 480 mA 110V AC 60 mA 100 mA 140 mA 180 mA 220V AC 35 mA 60 mA 80 mA 110 mA • Adjustable from 5 to 25W (factory setting 20W) • 0.5 to 1 A • 59 tones siren.Specific customer tones can be recorded in factory • Until 115 dB at 1m • 2 x M20, M25**, 1/2” NPT**, 3/4” NPT** or other** (Specify) • From 22 to 14 AWG - from 0.50 mm² to 2.5 mm² • 8.0 Kg • 25Hz <f<50Hz 40V<u<100V Z = 2k Ohms * = without runoff - ** = optional - cable gland and blind plug not provided MEANING OF LENS COLOR USAGE IN THE INTERNATIONAL STANDARD (IEC 60073) COLOR RED AMBER GREEN BLUE CLEAR MEANING EMERGENT ABNORMAL SAFE MANDATORY NO SPECIAL SIGNIFICANCE ACTION Dangerous state Take immediat action Abnormal state, near the critical status Normal state Requires operator’s action If uncertainty for other colors, clear is allowed to be used EXAMPLE • Pressure/Temperature beyond the safe state - Shutdown due to the action of protective devices - Fire alarm - Equipment failure alarm • Pressure/Temperature above the normal range - Protective device released - Toxic and harmful gases release alarm • Pressure/Temperature in normal state - Automatic control system is operating normally • Emergency evacuation - Abandon rescue and escape - Abandon platform or abandon ship - Enter the command • General information - Can’t exactly use red, yellow, green or blue Used for the implementation of command - Indicate the measured values www.semcomaritime.com · 2 03. 12 . 2015 | 5DSSB125-1 | page 2/2
Download PDF file
Build your own flipbook
FOLLOW US :